Tanks Inspection & Monitoring
Separators Inspection & Monitoring
Pipeline Integrity
Valves
Facilities
Drilling
Utilities
The Non-intrusive retrofit corrosion / erosion monitor helps detect changes to the wall thickness of a pipe section over time. This is achieved through real-time readings to new stand-alone system or existing Master Control System.
It has the following minimum specifications:
- Method of installation: Non-intrusive
- Maximum coverage area: 3 m² (32 ft²)
- Wall thickness range: 8 to 50 mm (0.315″ to 1.968″)
- Wall material: Conductive metals and alloys
ClampOn Subsea Corrosion-Erosion Monitor
Topside
- Minimum pipe OD: 114 mm (4″)
- Design life: 25 years
- Repeatability: Better than 1%
- Electronics: 32 channel main unit and PC/ automation controller
- Communication: Serial, Modbus, Ethernet, OPC
- System Supply voltage: 18 VDC to 32 VDC or 100-260 VAC 50-60Hz
- Pipe temperature: -40 °C to 180 °C (-40 °F to 356 °F)
- Ambient temperature: -40 °C to 60 °C (-40 °F to 140 °F)
- Cable interface: Cable with connector/Flying lead/Gland for cable access
- Cabeling Minimum: 4x 0.75 mm2 – Pending system configuration
ClampOn Topside Corrosion-Erosion Monitor
Subsea
- Changes: 0.1 %
- Design life: 30 Years (10+ Years for ROV mounted system)
- Electronics: 8/16 channel CEMAT with automation controller
- Communication: SIIS L3 (Modbus TCP/IP) or Serial RS485 (Modbus RTU)
- Design depth: 3050 m (10.000 ft)