ClampOn’s Non-intrusive retrofit leak monitor, help detect and quantify leaks across flow line valves, flanges or any other component in an oil / gas production system that can compromise safety or may lead to a shut down. This is achieved through real-time readings to new stand-alone system or existing Master Control System.
ClampOn Topside Leak Detector
It has the following minimum specifications:
- Method of installation: Non-intrusive
- Minimum detectable leakage: Gas: dP>1 bar, min. leakage rate 0.1 l/min
- Liquid: dP>3 bar, min. leakage rate 0.1 l/min (depending on delta pressure [dP] over the leakage point)
- Repeatability: Better than 1%
- Two-way communication: Yes
- Flow regimes: Oil, gas, water, multiphase
ClampOn Subsea Leak Detector
Topside
- Interface options: RS485 (ASCII, binary, ModBus RTU), 4-20mA
- Software upgrading: Yes
- Ambient temperature: ‐50 °C ≤Tamb ≤ +85 °C (Ex d) ‐40 °C ≤Tamb ≤ +60 °C (Ex i)
- Diagnostic features: Intelligent “health check”
- Ingress protection: IP66/IP68 (1 meter for 24 hours) in accordance with IEC 60529 Ex approval Ex d / Ex i
- Power Consumption: Typical 1.2 W @24 VDC
Subsea
- Interface options: Digital RS485 (ASCII, binary, ModBus RTU), 4-20mA (active/passive). Relay
- Pipe Surface Temperature: -40 °C to +225 °C (-40 °F to +437 °F)
- High temperature fixture: Yes – up to 500 °C (932 °F)