Tanks Inspection & Monitoring
Separators Inspection & Monitoring
Pipeline Integrity
Valves
Facilities
Drilling
Utilities
ClampOn’s Non-intrusive retrofit detector helps detect Pigs without requirement for any type of insert without the need for any shutdown. Providing real-time indication locally or remotely.
It has the following minimum specifications:
- Type of Pig: All types
- Minimum Pig Speed: 0.03 meter per second
- Installation principle: Non-intrusive
ClampOn Subsea Pig Detector
Topside
- Location rating: Ex ia: Zone 0, Ex de/m: Zone 1, Cl I Div 1 Gr. A,B,C,D
- Certification code: Ex ia: Ex ia IIB T2-T5, Ex de/m: Ex dem IIC T5
- Ambient temperature: -40 °C to 60 °C [-40 °F to 140 °F]
- Pipe temperature: -40 °C to 150 °C [-40 °F to 300 °F]
- Power supply: 12-30VDC – 1W typical/2W max per detector
- Communication: Relay, 4-20 mA, RS-485 (Modbus RTU, ClampOn DSP protocol)
- Ingress protection: Ex ia: IP 66&68, Ex de/m: IP 66&67
- Certifying bodies: IECEx, ATEX, CSA C&US, INMETRO, cCSAus, cULus
ClampOn Topside Pig Detector
Subsea
- Interface options: Digital RS485 (ASCII, binary, ModBus RTU), 4-20mA (active/passive), Relay, reset
- Options for ATEX approved sensors: local light/reset
- Options for subsea: CANBus, Profibus
- Two-way communication: Yes
- Software upgrading: Yes
- Operating Temperature: -40 °C to +150 °C (-40 °F to +302 °F)
- High temperature fixture: 500 °C (932 °F)
- Flow regimes: Oil, gas, water, multiphase
- Diagnostic features: Self test, vibration, 0.25Hz – 1000Hz ±5G